Part Description

The Hypertherm 006079 solenoid valve is a 120# 1/8 FPT 120V 3W valve. It is used to control the flow of gas or liquid in a variety of applications, including welding, cutting, and heating.

Features

Applications

The Hypertherm 006079 solenoid valve is ideal for use in a variety of applications, including:

Specifications

| Specification | Value | |---|---| | Brand | Hypertherm | | Part number | 006079 | | Part description | Solenoid valve | | Pressure rating | 120# | | Port size | 1/8 FPT | | Voltage | 120V AC | | Power consumption | 3W | | Normally closed | Yes |

Installation

The Hypertherm 006079 solenoid valve can be installed in any orientation. However, it is recommended that the valve be installed in a vertical position with the solenoid coil facing up. This will help to prevent the accumulation of moisture and debris in the valve.

To install the valve, follow these steps:

  1. Turn off the power supply to the valve.
  2. Disconnect any existing piping from the valve.
  3. Thread the valve into the desired location.
  4. Tighten the valve until it is snug.
  5. Reconnect the piping to the valve.
  6. Turn on the power supply to the valve.

Operation

The Hypertherm 006079 solenoid valve is a normally closed valve. This means that the valve is closed when the solenoid is not energized. When the solenoid is energized, the valve opens.

To operate the valve, simply apply power to the solenoid coil. The valve will open and allow flow through the valve. When the power is removed from the solenoid coil, the valve will close.

Maintenance

The Hypertherm 006079 solenoid valve requires very little maintenance. However, it is important to inspect the valve regularly for signs of wear or damage. If the valve is damaged, it should be replaced immediately.

To inspect the valve, follow these steps:

  1. Turn off the power supply to the valve.
  2. Disconnect any existing piping from the valve.
  3. Remove the valve from the desired location.
  4. Inspect the valve for signs of wear or damage.
  5. If the valve is damaged, replace it immediately.

Troubleshooting

If the Hypertherm 006079 solenoid valve is not working properly, there are a few things you can check:

If you have checked all of these things and the valve is still not working, you may need to replace the valve.

Similar Parts

006032
SOLENOID VALVE: 150# 1/4 FPT 120V NC

006014
SOLENOID VALVE: 90# 1/4 FPT 120V NC

006106
solenoid valve, 1/8 FPT, 120 V

006082
SOL VALVE:120# 1/8FPT 120V 3W..

006095
Solenoid Valve 120V

006100
Solenoid Valve 150# 1/8 FPT Pin

006109
Solenoid Valve for HPR/HD4070 for an Off Valve Assembly SV1 and SV2, SV4-SV9, SV11-SV16

229965
SOLENOID VALVE:06151 XPR CONSOLE SELECTION VALVE TESTED

006057
SOL VALVE:150# 1/8FPT 120V 3W..

006107
SOL VALVE:1/8FPT 120V SPCLPLG..