Monthly Basis
What's happening this month?

Hypertherm 120762 Noz/Shld Assy, 200 A A

Product Description

The Hypertherm 120762 Noz/Shld Assy, 200 A A is a high-quality replacement part for Hypertherm plasma cutting torches. This assembly includes a nozzle and shield, which are essential for proper torch operation. The nozzle helps to focus the plasma arc, while the shield protects the torch tip from damage. This assembly is made from durable materials and is designed to withstand the high temperatures and pressures of plasma cutting.

Features

  • High-quality replacement part for Hypertherm plasma cutting torches
  • Includes a nozzle and shield
  • Nozzle helps to focus the plasma arc
  • Shield protects the torch tip from damage
  • Made from durable materials to withstand high temperatures and pressures

Specifications

  • Brand: Hypertherm
  • Part number: 120762
  • Part description: Noz/Shld Assy, 200 A A
  • Amperage: 200 A
  • Material: Copper

Compatibility

The Hypertherm 120762 Noz/Shld Assy, 200 A A is compatible with the following Hypertherm plasma cutting torches:

  • Powermax30 XP
  • Powermax45 XP
  • Powermax65 XP
  • Powermax85 XP
  • Powermax105 XP
  • Powermax125 XP

Installation

The Hypertherm 120762 Noz/Shld Assy, 200 A A can be installed by following these steps:

  1. Turn off the power to the plasma cutting torch.
  2. Remove the old nozzle and shield assembly.
  3. Clean the torch tip and the area around it.
  4. Apply a small amount of anti-seize compound to the threads of the new nozzle.
  5. Screw the new nozzle onto the torch tip.
  6. Tighten the nozzle until it is snug.
  7. Install the new shield.
  8. Turn on the power to the plasma cutting torch.

Troubleshooting

If you are experiencing problems with your Hypertherm plasma cutting torch, the following troubleshooting tips may help:

  • Check the nozzle and shield for damage. If either of these parts is damaged, it will need to be replaced.
  • Make sure the nozzle and shield are properly installed. If either of these parts is not installed correctly, it can cause problems with the torch.
  • Clean the torch tip and the area around it. If the torch tip is dirty, it can cause problems with the arc.
  • Check the power supply to the torch. Make sure the power supply is providing the correct voltage and amperage.

If you are still experiencing problems with your Hypertherm plasma cutting torch, please contact Hypertherm customer support for assistance.

Conclusion

The Hypertherm 120762 Noz/Shld Assy, 200 A A is a high-quality replacement part for Hypertherm plasma cutting torches. This assembly is essential for proper torch operation and is made from durable materials to withstand the high temperatures and pressures of plasma cutting. If you are experiencing problems with your Hypertherm plasma cutting torch, the troubleshooting tips in this document may help.

Similar Parts

020337
NOZ:*MAX100/PAC130 100A SHLD

220542
NOZ ASSY:HPR 260A MS BEVEL

020424
Hypertherm Shield Cap/200 Amp Max 200 HT 2000

220021
electrode, 200 amps Air or Oxygen for Max 200

041147
PCB ASSY:200/4X00/HD PWR DI

041762
PCB Assy: HT 2000/Max 200, Control Board

228117
PHC LIFTER ASSY:W/MOT/BRK/MAG BRK-AWAY ASSY-0224

223510
CABLE:6M/19.7FT ETHERCAT M/M RJ45 FLEX SF/UTP SHLD

223512
CABLE:10M/32.8FT ETHERCAT M/M RJ45 FLEX SF/UTP SHLD

223511
CABLE:7.5M/24.6FT ETHERCAT M/M RJ45 FLEX SF/UTP SHLD