Hypertherm Navigator CNC Monitor CRT Replacement Kit
Part number: ASSY-0242
This kit includes the following items:
- CRT monitor
- Bezel
- Mounting screws
- Documentation
Installation instructions
- Power down the CNC machine and disconnect all power sources.
- Remove the bezel from the old CRT monitor.
- Remove the four mounting screws that hold the old CRT monitor in place.
- Carefully remove the old CRT monitor from the CNC machine.
- Place the new CRT monitor in the CNC machine and secure it with the four mounting screws.
- Reattach the bezel to the new CRT monitor.
- Power on the CNC machine and verify that the new CRT monitor is working properly.
Troubleshooting
If you are experiencing problems with the new CRT monitor, please refer to the following troubleshooting steps:
- Check the connections between the CRT monitor and the CNC machine.
- Verify that the power supply to the CRT monitor is correct.
- Try a different CRT monitor to rule out a problem with the monitor itself.
- Contact Hypertherm technical support for further assistance.
Safety precautions
When working on the CNC machine, always follow these safety precautions:
- Wear safety glasses.
- Disconnect all power sources before working on the machine.
- Be aware of moving parts and sharp edges.
- Do not operate the machine if it is damaged or not working properly.
Similar Parts
123442
CNC interface cable - PS to CNC, 50 ft.
123443
CNC interface cable, power supply to CNC, 75 ft.
081259
CNC SOFTWARE: CNC: TRUESHAPE NESTING
428038
KIT:MAXPRO200 FILTER HOUSING REPLACEMENT
428156
KIT:DURAMAX HYAMP/LT HAND TORCH TRIGGER/SPRING REPLACEMENT
428039
KIT:MAXPRO200 PUMP MOTOR REPLACEMENT
428042
KIT:MAXPRO200 PRESSTRANSDUCER CABLE REPLACEMENT
428043
KIT:MAXPRO200 PUMP REPLACEMENT
428729
KIT:XPR PUMP & MOTOR REPLACEMENT
528057
KIT:FUEL GAS MIXING SUB ASSEMBLY:OPTIMIX REPLACEMENT